40-7705I-UM Page 10 Rev 4 March 16, 2007
Figure 3-2
3.1 Front Panel:
The front panel has the user display and controls. Figure 3-1 shows a view of the
front panel.
Tactile Response Sounder LCD Display Power Button Status Panel Alert Panel
Figure 3-1
3.1.1 LCD Display: The LCD is a 4-line display with 20 characters per line. It
shows messages for the 7705i. Use this in conjunction with the Alert panel to
interpret and acknowledge messages. There is also a tactile response sounder to
provide audible confirmation of a successful button activation.
In most modes of operation, the top line will be constant and usually displays the
LCD firmware version number and
AES copyright. Example:
Other lines will be used to display messages generated by the server. Refer to
Appendix B for a detailed explanation of server-generated messages displayed on
the LCD.
3.1.2 Power Button is used to turn On/Off and Reset the computer motherboard
integral to the MultiNet Receiver. Push to start up a
downed unit. Press and hold for 10 seconds to perform
an emergency shutdown (Not recommended for non-
emergencies).
3.1.3 Status Panel: Contains LEDs that indicate fault
conditions as described below: See Figure 3-2.
When any of the Status LEDs are activated to reflect a
failure, the LED on the Alert panel will also be
activated, causing the Alert Sounder to activate.
Pressing SILENCE will momentarily silence the Alert
Sounder for 30 seconds until message is cleared.
Pressing ACKNOWLEDGE will clear the Alert LED.
The status LED will not be “cleared” until the failure
has been corrected.
Receiver: Red Led - Indicates a hardware or system fault in the server.
These faults will include Printer Offline and LCD display faults.
CPU: Red Led - Indicates that the CPU or internal processor has
performed a reset either manually initiated or automatically by the internal
watchdog circuit. Pressing the Acknowledge button turns off this LED.
Ethernet: Red Led - Indicates a fault condition with the Ethernet
connection as detected by a missing check-in from a 7170 IP-Link
Transceiver.